EJA110E
Differential Pressure Transmitter
J=Output signal :4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)
M=Measurement span : 1 to 100 kPa (4 to 400 inH2O)
S=Wetted parts material : Cover flange and process connector: ASTM CF-8M, Capsule:Hastelloy C-276 (Diaphragm)F316L SST, 316L SST (Others), Capsule gasket:Teflon-coated 316L SST, Vent/Drain plug:316 SST
4=Process connections : with 1/2 NPT female process connector
J=Bolts and nuts material: B7 carbon steel
9=Installation : Horizontal piping and left side high pressure
1=Amplifier housing : Cast aluminum alloy
4=Electrical connection : M20 female, two electrical connections without blind plugs
E=Integral indicator: Digital indicator with the range setting switch (push button)
B=Mounting bracket : 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
SF22=IECEx:IECEx Flameproof Approval
Applicable Standard: IEC 60079-0, IEC 60079-1, IEC 60079-31
Certificate: IECEx DEK 14.0046X
Enclosure: IP66/IP67
Ex db IIC T6...T4 Gb, Ex tb IIIC T85°C Db
Amb. Temp. (Tamb) for gas-proof :
T4; –50 to 75°C (–58 to 167°F), T5; –50 to 80°C (–58 to 176°F), T6; –50 to 75°C (–58 to 167°F)
Process Temp. for gas-proof (Tp):
T4; –50 to 120°C (–58 to 248°F), T5; –50 to 100°C (–58 to 212°F),
T6; –50 to 85°C (–58 to 185°F)
Max. surface Temp. for dust-proof: T85°C (Tamb: –30 to 75°C, Tp: –30 to 85°C)
D1=Calibration units : P calibration (psi unit)
M11=Material certificate : Cover flange, Process connector